TRX7010
TRX7010
Automated Clinical Chemistry Analyzer Compact and High Performance
TRX7010 is a bench top Clinical Chemistry analyzer, which has air pressure mixing to avoid carry over. The advanced Windows-based software, user-friendly interface ensures the TRX7010 offers many benefits.
* User friendly and easy to operate - The analyzer is simple to use via Windows-based user interface. Data entry is fast and efficient. It has alarm and warning messages to alert the user.
* Air pressure mixing - No reagent carry-over between tests because mixing is done with air pressure, without stirrers.
* Bichromatic optical system.
* Reusable special plastic reaction cuvettes with automatic washing system.
* Bi-directional LIS communication - Easy integration with existing laboratory information system.
Analysis
* System type: Discrete, single line random acces, multi-test analyzer
* Optical Absorption: Cuvette direct measurement (1 or 2 wavelenghts)
* Number of test items on board: 36+3(ISE) or 24+3(ISE)
* Throughput: 240 tests/hour
* Start-up time: ± 12 min.
* Analysis method: End point, 2 points end, Rate, 2 points rate linear, factor, non-linear (Logit-log, Spline, Exponential, Polynomial)
* Calculation: Calculation based on user's formula Correlation factor
* Number of test on board: 24 or 36 (option) items max.
* Programmable parameters: 77 photometric tests, 3 ISE tests and 15 formulas
Sample
* Sample kind: Serum, plasma, urine, CSF
* Sample container: Sample cup, micro cup, Primary tube (5, 7, 10 ml)
* Calibration tray: Standart sample = 45, Control sample = 6, Blank sample = 2, ISE Calibrator = 1, ISE cleaning solution = 1
* Patient sample tray: Patient sample = 40, Control sample = 6, STAT sample = 5, Cleaning solution = 2, ISE cleaning solution = 1
* Number of sample tray: Maximum 10 (2 trays are supplied)
* Sample dispense volume: 3-30 µL (0.5 µL step)
* Automatic dilution: Dilution ratio: 10 ~ 100
* Sample re-run: Automatic or manual
* STAT sample measurement: Interruption permitted even during analysis
* Sample idetification: Barcode ID, Position ID
* Sample probe: With liquid sensor and independent washer
* Tray exchange indicator: Safety lamp
Reagent
* Number of bottles on board: 72 (36 items) or 48 (24 items)
* Bottle volume: 20 mL, 40 mL, 60 mL, or 13 mL, 26 mL (option)
* Reagent dispense volume: 20-330 µL (5 µL step)
* Reagent storage: Cooled at 10 ± 2°C
* Inventory: Calculation of remaining reagent volume available
* Reagent tray: 24 sectors, 36 sectors (Option)
* Reagent identification: Barcode ID, Position ID
* Reagent probe: 2 separated reagent probes (R1 and R2) with liquid sensor and independent washer
* Tray exchange: Possible with reagent bottles
* Tray exchange: Safety lamp
Reaction
* Reaction cuvette: Material:special plastic to avoid carryover especially for latex reagent. Optical path length: 8 mm
* Reaction volume: 400 µL max. 200 µL min.
* Mixing method: 2 rooms air pressure mixing (without stirrer)
* Reaction time: 10 min. (1st reaction: 5min. 2nd reaction: 5min.)
* Reaction temperature: 37 ± 0.1°C
* Temperature control: Microprocessor
* Photometry: Mono and bichromatic, Multiwavelength grating photometer with 12 wavelengths: 340,380,405,505,546,570,600,660,700,750, and 800 nm
* Optical source: Tungsten halogen lamp
* Optical range: OD 0-2.5
* Photometric accuracy: ± 0.5%
* Drift (daily): ± 0.001 OD
* Precision of photometer measurement: 0.1% (CV) at 1.0 OD
* Wavelength accuracy: ± 2 nm
* Cuvette washing: Auto wash with heated water and 2 kinds of washing solution
* Probe washing: Sample and reagent washing stations
* Reaction waste collection: Separated between concentrated and diluted reaction waste
User Interface
* Operating system: Windows®
* Software: The colorfull interface of software is friendly and easy to operate
* System interface: RS-232
* Run monitor: Analysis progress display, Reaction residual time estimation
* Reaction curve monitor: Reaction curve graphic display
* Result: Print out and display
* Printer: Built-in thermal printer (internal), External printer (option)
* Auto flagging: Abnormal result
* Quality Control: Westgard multirule, Levy-Jennings Plot, XB charts within day, day to day
* Voice message: "Sampling stop","End of Analysis" etc.
* Alarm: Washing solution and washing water low level alarms, Waste liquid tank high level alarm
* Warning: Lack of sample or reagent
* Data storage capacity: Up to 6 months, Reaction absorbance:9999 tests
* External storage: Floppy disk, USB
* External printer (option)
Technical specifications
* Power Supply: AC 100V, 115 V, 230 V ± 10%;600 VA 50/60 Hz
* Grounding: Special 3rd grade, Resistive less than 10 ohm
* Ambient temperature: 15-30°C (During operation)
* Ambient humidity: 30-85% (No condensation)
* Water consumption: 3.5 liters/hour
* Dimensions: 800(W) x 640(D) x 520(H) mm
* Weight: ± 95 kg
Test items
* Biochemistry-Substrate: Albumin, BUN/Urea, β-lipoprotein, Bilirubin-Direct, Bilirubin-Total, Calcium, Cholestrol, Cholestrol-HDL, Cholestrol-LDL, Creatinine, Free-Fatty Acid (Non-Esterified), Fructosamine, Glucose, HbA1c, 3-Hydoxybutyric Acid, Inorganic Phosphorus, Iron, Lipoprotein(a), Micro-Albumin Urine, Magnesium, Micro-Total Protein (Urine), Phospholipid, Sialic Acid, Total Bile Acid, Total Ketone Body, Thymol Turbidity Test, Zinc Sulfate Turbidity Test
* Biochemistry-Enzyme: Acid Phosphatase, Adenosine Deaminase, Alkaline Phosphatase, ALT, AST, AST-Mitochondrial, Amylase, Amylase-Pancreatic, Cholinesterase, CK-NAC, CK-MB, Gamma-GT, α-Hydroxybutyrate Dehydrogenase, Leucine Aminopeptidase, Lactate Dehydrogenase, Lipase, Monoamine Oxidase, N-Acetyl-β-Glucosaminidase
* Immunology: Antistreptolysin-O, Apoa-I, Apoa-II, ApoB, ApoC-II, ApoC-III, ApoE, β2-microglobulin C-reactive Protein, C3, C4, CH50, lg-A, lgG, lg-M, Rheumatoid Factor, Transferrin, Treponema Pallidum
* Drug: Carbamazepine, Digoxin, Phenobarbital, Phenytoin, Primidone, Theophylline, Valproic Acid
* Coagulation: Antiplasmin, Antithrombin III, Fibrin Degradation Product, D-Dimer, Plasminogen, Protein C
Product ordering information
TRX7010: #101024026631
TRX7010 with sample barcode reader: #101024026632
TRX7010 with sample and reagent barcode reader: #101024026633