Biolis 50i Superior

Biolis 50i Superior


The Best Solution for Clinical Chemistry Laboratory

Biolis 50i Superior is the highest throughput in Biolis series, which has automatic sample clot detection and cleaning, rapid correspondence by a new function for HbA1c.

* The highest throughput in Biolis series, 480 test/hour for photometry.
* Automatic hemolysis of whole blood sample for HbA1c.
* Automatic cleaning of the sample probe when clots are detected helps to ensure high-accuracy test results.
* Accuracy Features - Carry-over protection program for reaction cuvettes and probe, cuvette skip and pre-dilution.
* User interface - a touch screen allows easy and efficient operation. This analyzer features a logical multi-lingual and the Windows-based software enables easy connection to a host computer and printers.
* Bi-directional LIS communication - Easy integration with existing laboratory information system.

Analysis
* System type: Discrete, Fully selective multi analyzer system
* Number of test items on board: 36+3(ISE)
* Throughput: 480 tests/hour, 160 tests/hour for HbA1c only (with hemolysis), 580 tests/hour including ISE
* Analysis method: One and two End Point Assay, One and two Rate Assay
* Calibration Curve: 8 kinds (Two points Linear, Multi-points Linear, Factor, Logit.log 1, Logit.log 2, Spline, Exponential, Polynomial)
* Optical Absorption: Cuvette direct measurement (1 or 2 wavelengths)
* Calculation between items: Calculation based on user’s formula and correlation factor

Sample
* Sample kind: Serum, plasma, urine, dialysis, CSF
* Sample container: Standart cup, micro cup, Primary tube (5, 7, 10 ml)
* Number of sample on board: 72 patient or standard samples, 30 QC and/or STAT samples
* Sample dispense volume: 1-20 µL (0.1 µL step)
* Automatic dilution: Dilution ratio: 3 ~ 100
* Cooling temperature: 18-20°C (QC sample only)
* STAT: Available during measurement
* Sample barcode: Available

Reagent
* Number of bottles on board: R1: 36 positions, R2: 35 positions
* Bottle size: R1: 70 mL, R2: 20 mL
* Reagent dispense volume: 20-240 µL (0.5 µL step)
* Reagent storage: 8-12°C (24 hours)
* Residual volume: Level sensing or count down calculation
* Reagent barcode: Available

Reaction System
* Cuvette Material: Plastics (Semi-disposable)
* Number of cuvette: 90
* Reaction volume: Minimum 120 µL
* Reaction time: Max. 8.5 min. (1st reaction: 3.5 min. 2nd reaction: 5 min.)
* Reaction temperature: 37 ± 0.3°C
* Cuvette skip function: Available
* Optical measurement: 12 fixed wavelengths (340,380,405,505,546,570,600,660,700,750, and 800 nm)
* Wavelength accuracy: ± 2nm
* Optical detector: Silicone photo-diode
* Optical source: Tungsten halogen lamp 12 V 20 W
* Optical range: OD 0-3.0
* Optical path length: 5mm
* Mixing speed: 5 speed levels available
* Cuvette washing: Auto washing with heated water and 2 kinds of washing solution
* Washing solution: Alkaline and Acidic
* Photometric assay method: Grating method
* Reaction waste collection: Reaction waste to be stored in a dedicated tank

User Interface
* Operation: Easy touch screen PC
* Operating system: Windows™ 7 Profesional
* Language: Bahasa Indonesia, English
* Run monitor: Analyzer operation status display
* System interface: RS 232C serial cable, LAN (TPC/IP)
* Reaction curve monitor: Optical absorbance graphic display
* Quality Control: Real time QC within day, day to day variation
* Voice message: Announce test status
* Test result storage: 100.000 tests
* Printer: External and internal
* Reporting: Patient and QC (daily and cumulative report)

Technical specifications
* Pure water consumption: Max 15 L/hour
* Water purification system: RO-Lite direct purification
* Water quality: Distilled water equivalent (1 - 10 μS)
* Pure water tank cap.: 10 L (when it is filled up)
* Reaction waste tank cap.: 10 L (when it is filled up)
* Power Supply: AC 100V, 115 V, 230 V ± 10%;600 VA 50/60 Hz
* Grounding: Special 3rd grade, Resistive less than 10 ohm
* Ambient temperature: 15-30°C (During operation)
* Ambient humidity: 30-85% (No condensation)
* Dimensions: 1050 mm (W) x 750 mm (D) x 1145 mm (H)
* Weight: Instrument: Approx. 290 Kg

Test items
* Biochemistry-Substrate: Albumin, BUN/Urea, Bilirubin-Direct, Bilirubin-Total, Calcium, Cholestrol, Cholestrol-HDL, Cholestrol-LDL, Creatinine, Free-Fatty Acid, Glucose, HbA1c, Phosphorus, Iron, Uric Acid, Total Protein, Ferritin, UIBC, Microalbumin, Total Protein (Urine), Magnesium, Phospholipid
* Biochemistry-Enzyme: Acid Phosphatase, Alkaline Phosphatase, ALT, AST, Amylase, Amylase-Pancreatic, Cholinesterase, CK-NAC, CK-MB, Gamma-GT, α-Hydroxybutyrate Dehydrogenase, Lactate Dehydrogenase, Lipase
* Immunology: Antistreptolysin-O, Apoa-I, Apoa-II, ApoB, ApoC-II, ApoC-III, ApoE, β2-microglobulin C-reactive Protein, VDRL, C3, C4, CH50, lg-A, lgG, lg-M, Rheumatoid Factor, Transferrin, Treponema Pallidum
* Drug: Carbamazepine, Digoxin, Phenobarbital, Phenytoin, Primidone, Theophylline, Valproic Acid
* Coagulation: Antiplasmin, Antithrombin III, Fibrin Degradation Product, D-Dimer, Plasminogen, Protein C

Product ordering information
Biolis 50i Superior

Contact Us

  • Address: Perkantoran Plaza Pasifik B2/41, Jalan Boulevard Barat Raya, Kelapa Gading, Jakarta Utara 14240 - Indonesia

  • Phone: (021) 45845736

  • Email: support@diapro.co.id